Gutter shall have a maximum of 5 slope from flowline within w area with x area if provided to be used.
City of los angeles curb and gutter detail.
Curb line detail 5 r 1 elevation 8 33 max detail 1 detail 2 detail 3 0 5 2 detail 4 plan detail 6 5 a 5 b 5 a 5 b 5 a 5 b 5 a 5 b.
Joints in concrete pavement.
Standards plans are a time saving tool that is advantageous for structures that are built repeatedly where the design and construction are not expected to vary greatly from site to site the use of a standard plan greatly reduces the time required for plan check.
Standard curb ramps detectable warning layout details and notes.
Typical details can be found in the.
Permits can therefore be issued much faster for structures such as swimming pools metal patio covers stairways signs etc.
However please note that certain information may only be available to city employees.
S4102 1 s4102 2 s4102 3 s4102 4.
Alternate curb ramps merged curb ramp plans.
Sm 5 standard dwg for driveway curb combined curb and gutter.
Alternate curb ramps with constrained sidewalk widths.
Weakened plane joints in curb and gutter shall conform to standard specifications for public works construction subsection 303 5 4 3 c or shall be i 112 inch deep sakuts made within io to 24 hours arer concrete is placed and shall be placed at locations shown on the typical joint plan hereon and at regular intervals not exceeding 20 feet between returns.
Alternate curb ramps merged grooved border curb ramp plans.
Types of curb and gutter.
Alley approach and p c c.
Department of public works los angeles county.
City of los angeles standard plan s 442 4 supersedes references b 4571 vault index number.
City of santa monica standard details standard street improvement details.
V curb extensions restricting the width of intersections through the use of curb extensions may be desired to promote traffic calming and pedestrian safety.
Sm 3 portland cement concrete alley.
Two 3 8 inch or larger diameter reinforcing bars 18 inches long shall be imbedded in the curb.
Standard street crown sections.
Manuals and standardsthe bureau of engineering offers access to specific data to citywide users.
Extruded asphalt concrete ac curb.
Where the curb face is 6 inches or less in height the invert of the outlet may be placed at the elevation of the gutter flow line and or a 3 inch pipe may be used.
Sm 6 standard curb and gutter construction.
The location and frequency of the curb extensions are to be based upon the recommendations of the traffic consultant and subject to county approval.